Thermal Endurance
20,000 hr Life >210°C
Thermoplastic Flow
min : 300°C
typical : 350°C
Heat Shock (20% 3x)
½ hr @ 220°C min : no cracks
½ hr @ 240°C min : no cracks
Solderability
@ 480°C (900° F) : No
Stress Relief Temp: 160°C
MECHANICAL

Mandrel Flexibility
After Elongation
min : 20% 3x OK
typical : 30% 1x OK
After Snap
min : 3x OK
typical : 1x OK
Unilateral Scrape
Avg of 3 sides
min : 1150 gms
typical : 1700 gms
Repeated Scrape
700 gms
min : 60 strokes
typical : 100 strokes
Dynamic C of F typical: 0.046
ELECTRICAL

Dielectric Breakdown
@ RT : 11 kV
@ 200°C : 7.0 kV
High Voltage DC Continuity
NEMA @ 1500 V DC : 5 faults/100 feet max
Typical @ 3000 V DC : 0-1 faults/100 feet
Corona Inception Voltage
typical: 580V
CHEMICAL

Retained Dielectric
After 72 hrs exposure to R-22 +300°C conditioning: 3.5kV
R-22 Extractables: 0.8%
Resistance to Solvents
| after 24 hrs @ RT : |
Pass
Solvents Including:
Xylene,
50/50 Cellosolve/Xylene,
Perchloroethylene,
1% NaOH,
28% Sulfuric Acid,
Gasohol |
Procedure followed to determine published values:
NEMA: National Electrical Manufacturers Association
JIS: Japanese Industrial Standards
IEC: International Electrotechnical Commission